Description
An additional, very important advantage of the EB-LCM11 controllers is the ability to connect transitions in so-called * airlock.
In addition, the controller has:
- A universal input that can be used e.g. to couple the operation of locks with a fire system. Its operation depends on the version of the program.
- Signal diode connector.
Technical parameters:
Power supply: |
DC voltage of nominal value 12V, Permissible supply voltage of the 10-17V module itself,
The power supply is taken from the controller through the FC14 connector. |
Power consumption: | The controller working independently consumes 50 to 150mA, |
Connector LOCK P.SPLY | The connector is used to connect the lock power supply.
The maximum value of the lock load is: – 50V AC, 1A – 24V DC, 2A when using locks that require a higher supply voltage or higher power, an additional external relay should be used. |
Input UNIV. IN | Universal input, the operation of which depends on the software configuration. It can work in two modes, as a potential-free or voltage-controlled input. The operating mode depends on the settings of the JP1 and JP2 jumpers. High condition occurs when the pins are shorted.
50 ms input filter. |
Dimensions: | height 122mm, width 60, height of the highest element 20mm |