Description
An additional, very important advantage of the EB-LCM21 controllers is the possibility of connecting passages in the so-called airlock * single or double.
In addition, the controller has:
- Universal input. Its operation depends on the version of the program.
- FIRE ALM input. used to integrate the door with the fire protection system.
- This input can also be used, if necessary, as a universal input.
- Universal output. Its operation depends on the version of the program.
- May among others serve together with the universal entrance as a second lock connection.
- Signal diode connector.
Technical parameters:
Power supply: | DC voltage with nominal value of 12V, 10-17V module supply voltage,
The power supply is taken from the controller through the FC14 connector. |
Power consumption: | The controller working independently consumes from 30 to 150mA, |
Connector LOCK P.SPLY | The connector is used to connect the lock power supply. The maximum value of the lock load is: – 50V AC, 1A – 24V DC, 2A when using locks that require a higher supply voltage or higher power, an additional external relay should be used. |
Inputs | EB-LCM21 is equipped with 2 inputs: – UNI.IN a universal input whose operation depends on the software configuration. It can work in two modes, as a potential-free or voltage-controlled input. The operating mode depends on the JP1 and JP2 jumper settings
– FIRE ALM. fire alarm input intended for cooperation with fire alarm control panels. It can also be used as a universal input. Works only in potential-free mode High condition occurs when pins short-circuit. 50 ms input filter. |
Outputs | The controller is equipped with one universal relay output (COM, NO, NZ). The output load is:
– 50V AC, 1A – 24V DC, 2A |
Dimensions: | height 122mm, width 120mm, height of the highest element 50mm |