Description
Technical parameters:
Input TRAFO1 | 3V minimum voltage Maximum 45V voltage Maximum current consumption 3A The input should be protected by an external 3A fuse |
Input TRAFO2 | Minimum voltage 12V Maximum voltage 24V Maximum current consumption 3A The input should be protected by an external 3A fuse |
Output DC OUT1 | Unstable voltage with a value corresponding to the input voltage supplied to the TRAFO1 input, reduced by 1.5V. The maximum current that can be drawn from the output depends on the degree of utilization of the other outputs. The total current drawn from all three outputs can be 3A. When we use only the first output, we can load it with 3A current. |
Output DC OUT2 | Unstable voltage with a value corresponding to the input voltage supplied to the TRAFO1 input, reduced by 1.5V. The maximum current that can be drawn from the output depends on the degree of utilization of the other outputs. The total current drawn from all three outputs can be 3A. When we use only the first output, we can load it with 3A current. |
Output 12V STAB. | Stabilized output voltage of 12V. The maximum output current that can be drawn from the output depends on the load on the other outputs and the power supply input. In case we only use this output: Maximum current, with a supply voltage in the range from 12 to 15V, fed to the TRAFO2 input is 0.5A. However, it is recommended to use voltages from 16 to 24V at which the stabilizer achieves maximum current efficiency, 3A. |